Line Sizes
DN200 to DN900 (8-in to 36-in)
Fluid Type
Liquified natural gas (LNG)
Linearity
±0.15% of measured value over a 1.2 to 12.2 m/s (4 to 40 ft/s) range or ±0.20% of measured value over a 0.6 to 12.2 m/s (2 to 40 ft/s) range (optional)
Uncertainty of Meter Factor
<±0.027% (API MPMS, Chapter 5, Section 8, Table B-1)
Velocity
0.6 to 12.2 m/s (2 to 40 ft/s) with an extended range of 0.3 to 14.6 m/s (1 to 48 ft/s)
Temperature Range
Transducers: -196°C to +60°C (-385°F to +140°F)
Electronics (ambient): -40°C to +60°C (-40°F to +140°F)
Pressure Range
0 to 250 Bar (0 to 3,600 psig)
Specific Gravity Range
0.35 and higher (nominal 0.45)
Materials
Carbon steel and stainless steel
Calibration
Conducted in Emerson’s ISO 17025 certified flow calibration laboratory