The MTLT-6000 is based upon the magnetostrictive principle.

The sensing tube contains two wires which are pulsed with the magnetic field created by the magnetic float causes a torsion stress wave to be induced in the wire. The torsion propagates along the wire at a known velocity from the position of the magnetic float and toward both ends of the wire. The microprocessor-based electronics measure the elapsed time between the start and return pulses and convert it into 4-20mA DC output which is proportional to the level being measured.

Features

  • Modular design
  • High accuracy and repeatability
  • Multi-drop HART communication
  • Explosion-proof and / or intrinsically safe (model dependent)
  • No maintenance required

Specifications

Level Output

Measured Variable Product Level/Interface Level
Output 4-20mA, HART
Full Range Rigid Sensors: up to 10668 mm (420 in.)
Non-linearity Rigid Sensors Element: 0.20% F.S. (Independent BSL) or 0.794 mm (1/32 in.)
Repeatability 0.001% of full span
Sensor Operating Temperature -100°C (-150°F) to 121°C (250°F)**

Gauge Loop

Input Voltage Range 12-30 VDC, 24 VDC Nominal
Reverse Polarity Protection Series diode

Calibration

Zero Adjust Range Anywhere within the active length
Span Adjust Range Full Scale ≥ 152 mm (6 in.) from zero

Temperature Ratings

Electronics -40° C (-40° F) to 70° C (160°F)
LCD Readout -40° C (-40° F) to 70° C (160°F)
Standard -40° C (-40° F) to 114° C (235°F)
HT Version -40° C (-40° F) to 214° C (400°F)

Environmental

Humidity 0 to 99.00%, non-condensing
Materials (non-wetted parts) 316 stainless steel, CPVC, Hastelloy, Alloy 20

Field Installation

Mounting NPT fitting (3/4 in. rigid, 1 in. flex)
Wiring 2- wire connection, shielded cable or twisted pair to screw terminals through a 1/2 in. NPT conduit opening NEMA Type 4X: 15ft (457 cm) pigtail integral cable or Daniel Woodhead (Part No. 70807SS) 6 – pin Male 1/4 in. -18MNPT key-way receptacle, 3/4 in. NPT conduit opening of Ex housing

Display (Optional)

Measured Variables Level 1, Level 2
Update Rate 3 Seconds
Size 12.7mm (0.5 in)
Number of Digits 8

HART Communications

Method of Communication Frequency Shift Keying (FSK) conforms with Bell 202 Modem
Standard with respect to baud rate and digital “1” and “0” frequencies
Data Byte Structure 1 Start bit, 8 Data bits, 1 Odd Parity bit, 1 Stop bit
Digital Process Variable Rate Poll/Response Model 2.0 per second

Agency Approvals

FM (Canada & US)

Intrinsically Safe

Class I, Division 1 :
Groups A, B, C, D
Class II, Division 1 :
Groups E, F, G Class III,
NEMA Type 4X

Explosion-Proof

Class I, Division 1 :
Groups B, C, & D
Class II, Division 1 :
Groups E, F, G
NEMA Type 4X