Output variables
                                
                                
                                    Mass & volume flow
Net product content / flow
Temperature
Density
Concentration
                                
                             
                            
                                
                                    Local display
                                
                                
                                    Standard user interface with 2-line LCD panel
Two clips for HART/Bell 202 connections (requires removing transmitter housing cover)
Two membrane pushbuttons for local operation (requires removing transmitter housing cover)
Glass or plastic lens options
                                
                             
                            
                                
                                    Power
                                
                                
                                    Self-switching AC/DC input, automatically recognizes supply voltage
 85–265 VAC, 50/60 Hz, 4 watts typical, 7 watts maximum
18–100 VDC, 4 watts typical, 7 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) and Installation (Overvoltage) Category II, Pollution Degree 2
                                
                             
                            
                                
                                    Input/output signals (analog output option)
                                
                                
                                    Channel A:
One active 4–20 mA output
Not intrinsically safeChannel B (configurable), one of:
One active or passive frequency output
One active or passive discrete output
One active or passive discrete input
                                
                             
                            
                                
                                    Input/output signals (PROFIBUS-DP option)
                                
                                
                                    Digital 2-way PROFIBUS-DP signal
                                
                             
                            
                                
                                    Input/output signals (DeviceNet option)
                                
                                
                                    Digital 2-way DeviceNet signal (Now Obsolete)
                                
                             
                            
                                
                                    HART
                                
                                
                                    Bell 202 signal is superimposed on the primary milliamp output
HART communication is not available on PROFIBUS-DP and DeviceNet transmitter versions
                                
                             
                            
                                
                                    Mounting options
                                
                                
                                    Field mount, integral with sensor
                                
                             
                            
                                
                                    Application types
                                
                                
                                    Continuous process control
Two-phase flow/entrained gas
Meter verification
                                
                             
                            
                                
                                    Hazardous approvals
                                
                                
                                    C1D2
Zone 2