What is the Difference Between Restricted Trim vs. Relief Size in Regulators?

September 25, 2024

By Brian Nutter | Fisher Regulator Specialist

Regulators are commonly used in almost every industry around the world. Over the years I have worked with many different companies to size, select and troubleshoot regulators and pressure systems, and I receive a lot of the same questions around regulator trims and the effect these have on overall performance.

With this in mind, I would like to take this opportunity to address one of the main questions I hear quite often:​

“When we sized and selected the regulator, we used a Relief Size-Reduction (restrictor) trim to provide more travel at lower flows, but we are not getting improved performance or additional travel at low flow rates. Why doesn’t this work?”​

I will address this with a basic understanding of the different trim types and how they work for their intended purpose. Using the right solution is critical to providing optimum performance.

Restricted Flow Trim / Low Flow & Turndown

Oversizing – Improving Regulator Turndown using Restricted Trim​
Reduced orifice sizes and characterized cages are inexpensive ways of improving a regulator’s turndown capability. These restricted trims help low flow performance by increasing the travel at low flows, moving the valve plug further off the orifice.​
 ​
Restricted trim types that improve low flow performance:​
Changing to a smaller orifice (ex: numerous self-ops and a few pilot-ops)​
On products without alternate orifices, use a smaller body size or swaged body design (ex. 2” x 1”, or 4” x 2” body).

Use of Regulator Restricted Trims for Low Flows / High Turndown & Plug Level

An additional attribute of these restricted trims is that in many cases the wide-open flow is also lowered which can reduce the size of a relief valve being used for overpressure protection.

Confusion arises around “trims designed solely for reducing the wide-open flow” with users expecting them to improve low flow performance. Because these Relief Size-reduction Trims don’t affect the flow area size when the valve plug is at low travel, or when operating within the normal regulating range of flow. Under these conditions Relief Size-Reduction restriction trims do not improve turndown capability or increase plug travel at low flows.​

Restricted Trim vs Relief Size-Reduction Trim

Because Relief Size-Reduction Trims do not improve a regulator's turndown, use the 100% capacity when using turndown rules-of-thumb, not the reduced capacity.

To Sum it Up

As you can see, there are different ways to improve regulator performance when a regulator is either oversized, or if the turndown is high and the regulator struggles at low flows.

  • When sizing a regulator for high turndowns, look for the available orifice sizes, characterized trims, or swaged bodies that reduce the inlet connections to a smaller internal body size or orifice opening to handle low flows.
  • Using restricted trim or travel stops designed to reduce “Wide Open Flows” and to reduce relief valve size will not provide added travel at low flows or under normal flow ranges.  This should only be used to restrict the top end of flow in the event the regulator fails wide open and possibly reduce the size of the relief valve needed to accommodate the overall amount of flow.
  • When using the Relief Size-reduction trim, use the 100% flow capacity charts for sizing, and also to check the turndown.  This will give you a more accurate estimate of the travel associated with both the high and low flow conditions.
  • If possible, one more solution to handle high turndowns and to add travel to the regulator plug is to lower the inlet pressure so that the plug will need to move farther from the orifice to allow the same amount of flow.  This can only be used in systems where the inlet pressure can be adjusted, and both the high and low flow rates can be met with lower differential pressure across the regulator.

Submit Your Questions!

Do you have a question you’d like to “Ask an Expert”? We’d love to hear from you! Your question could be answered in a future blog post.

Ask Us

Relief Size-reduction Trim examples:
  • Travel stops (1098)
  • Upstream orifice plates (EZR, EZH, LSR)
1098 with Characterized Trim
 

About the Author

Brian Nutter

has over 35 years of experience with Fisher Regulators for use in Natural Gas, Transmission, Industrial and LPG Systems.

He joined Applied Control in 2001 and is the Business Manager for all Emerson Pressure Management Products.


Connect with brian on LinkedIn

Related Stories

Back To Top